CBTA | Industrial facilities

Solutions for high voltage Direct Customers

Picture 1 | Factory´s main LV switchboard using several CBTA: two CBTA using a 2500 A moulded case circuit breaker as incomers, and interconnection module, 2 extension modules with feeders BTVC and 2 LV panels with one pole NH fuse bases for 1 outgoing up to 1600 A.

Picture 2 | Combination of CBTA’s in UNESA enclosure consisting of 2 LV switchboards with load break switch as incomers, interconnection module, extension module and 2 power factor correction modules.

 

más información

Iberdrola

  • CMAT Telemetering | Used to contain the necessary equipments to measure the consumption in high voltage for outdoor and indoor installations of customers Type 1-2 & Type 3.
  • CMAT Free market Assembled in a PNT enclsoure for indoor applications.
  • CMAT | Assembled in a PNT enclsoure for indoor applications.

SPECIFICATIONS

CMAT Telemetering
Type 1-2 & 3
CMAT Free market CMAT
Installation Outdoor Indoor Indoor
Enclosure Polyester PNT PNT 77 TAC
Handle
PNT 75 CC
Handle (180º)
Mounting plate Thermostable polyester, mechannished to fix different equipments
Terminal block ID 10 Elements ID 10E 6I4T 10 Elements
Lock Cylinder lock ID
Protection screen No No Polycarbonate insulating
Meter fastening No Yes Yes
Earth No No No
Accessories Cable glands PG-36 No
Window No No No
Ventilation No No No
Fixing Rear by wall mounting set

Note: Rotation system available for handling of the mounting plate..

más información

Endesa

  • CMAT Assembled in indoor & outdoor
  • CMAT Insulated box small terminal block
  • CMAT Free market | 1 meter / 2 meters

SPECIFICATIONS

CMAT Indoor & Outdoor installation CMAT Insulated box small terminal block CMAT Free market
1
meter
2 meters
Installation Indoor (without roof)
Outdoor (with roof)
Indoor Outdoor
Enclosure Polyester PNT Insulated box PNT Polyester
55 TAC
Handle
PNT 77 TAC
Handle
Mounting plate Thermoestable polyester, mechanished to fix different equipments
Terminal block ID 10 Elements 10 Elements ID 10E 6I4T Endesa 10
Elements
Lock Endesa Cylinder lock
Protection screen No No No No
Meter fastening Yes No Yes Yes
Earth Yes No No No
Accessories No No 16 A socket protected with a 2 x 10 A
Modem frame (1u.)
Window No No No No
Ventilation DVG Ventilation devices No No No
Fixing Rear by wall mounting set
más información

Naturgy

Assembled in a PNT enclosure for outdoor applications.

  • CMAT 2 meter Type 1
  • CMAT 2 meters Type 2-3

SPECIFICATIONS

CMAT Type 1
2 meters
CMAT Type 2-3
2 meters
Installation Outdoor
Enclosure PNT 107 TAC Handle PNT Polyester 107 TAC
Handle
Mounting plate Thermoestable polyester, mechanished
to fix different equipments
Terminal block GNF 10 elements GNF 10 Terminal block for
10 elements
Lock GNF Cylinder lock
Protection screen Transparent insulating No
Meter fastening No Yes
Earth Yes (meters) No
Accessories Removable frame, socket protected by means of a breaker Removable frame / modem frame (2 u.) / 16 A socket protected by a  2×10 A 2P breaker
Window No No
Ventillation No No
Fixing Rear by wall mounting set
más información

CBTA UNESA | Circuit breaker | 4 outgoings

CBTAUIA4S-400*400

Metallic UNESA type CBTA
Circuit breaker

  • 4 feeders by means of fuse swtiches BTVC TRIVER+.
  • Suitable for power transformers from 400 kVA up to 1000 kVA.
  • It can be extended with a CBT-AM4.
Incoming Top
Rated current 630 A 800 A 1000 A 1250 A 1600 A
Installation Indoor
Enclosure Metálica UNESA type
Operation   3F+N Moulded case circuit breaker
Outgoing types BTVC TRIVER+*
No. of outgoings 4
Options
· Auxiliary circuits
· Locking device for switch
· Residual current protection
No. of incoming cables 4 x 240 mm2

* BTVC – Bases TRIVER+ tripolar vertical desconectable en carga.
El nº de salidas varía según se combine la gama del catálogo de bases
TRIVER+ NH 00/1/2/3.

Para más información, contacte con nuestro Departamento Comercial.

más información

Power factor correction LV switchboard

MODINTER-400*400
  • Power factor correction of the distribution transformer when the installation is running under reduced load or out of load.
  • Lateral connection following the same system as AM-4 modules.
Incoming  Lateral connection to the LV switchboards
Rated current  1600 A
Installation  Indoor
Enclosure  Metallic
Power capacitor  5% of the power transformer
Operation  Switch disconnector fuses
Outgoing types  BTVC TRIVER+*
No. of outgoings  2
Options 
No. of incoming cables
Weight  75 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información