Assembled in a PNT enclosure for outdoor applications.

  • CMAT 2 meter Type 1
  • CMAT 2 meters Type 2-3

SPECIFICATIONS

CMAT Type 1
2 meters
CMAT Type 2-3
2 meters
Installation Outdoor
Enclosure PNT 107 TAC Handle PNT Polyester 107 TAC
Handle
Mounting plate Thermoestable polyester, mechanished
to fix different equipments
Terminal block GNF 10 elements GNF 10 Terminal block for
10 elements
Lock GNF Cylinder lock
Protection screen Transparent insulating No
Meter fastening No Yes
Earth Yes (meters) No
Accessories Removable frame, socket protected by means of a breaker Removable frame / modem frame (2 u.) / 16 A socket protected by a  2×10 A 2P breaker
Window No No
Ventillation No No
Fixing Rear by wall mounting set
más información

CBTA UNESA | Circuit breaker | 4 outgoings

CBTAUIA4S-400*400

Metallic UNESA type CBTA
Circuit breaker

  • 4 feeders by means of fuse swtiches BTVC TRIVER+.
  • Suitable for power transformers from 400 kVA up to 1000 kVA.
  • It can be extended with a CBT-AM4.
Incoming Top
Rated current 630 A 800 A 1000 A 1250 A 1600 A
Installation Indoor
Enclosure Metálica UNESA type
Operation   3F+N Moulded case circuit breaker
Outgoing types BTVC TRIVER+*
No. of outgoings 4
Options
· Auxiliary circuits
· Locking device for switch
· Residual current protection
No. of incoming cables 4 x 240 mm2

* BTVC – Bases TRIVER+ tripolar vertical desconectable en carga.
El nº de salidas varía según se combine la gama del catálogo de bases
TRIVER+ NH 00/1/2/3.

Para más información, contacte con nuestro Departamento Comercial.

más información

Power factor correction LV switchboard

MODINTER-400*400
  • Power factor correction of the distribution transformer when the installation is running under reduced load or out of load.
  • Lateral connection following the same system as AM-4 modules.
Incoming  Lateral connection to the LV switchboards
Rated current  1600 A
Installation  Indoor
Enclosure  Metallic
Power capacitor  5% of the power transformer
Operation  Switch disconnector fuses
Outgoing types  BTVC TRIVER+*
No. of outgoings  2
Options 
No. of incoming cables
Weight  75 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTA envolvente poliéster | Load break switch | 4 feeders

CBTA using insulated PNT polyester enclosure is assembled in one cabinet with two independent doors:

  • Upper enclosure for the load break switch.
  • Lower enclosure for the feeders by means of fuse switches BTVC TRIVER+.

Suitable for power transformers up to 400 kVA.

Specifications of the CBTA PNT Premium – Load break switch:

Incoming Bottom directly to load break switch
Rated current 400/630 A
Installation Outdoor-Indoor
Enclosure Polyester PNT
Operation 3F+N load break switch
Outgoing types BTVC TRIVER+*
No. of outgoings 4
Options
  • Pole mounting frame
  • Locking device
No. of incoming cables 2 x 240 mm2
Weight 75 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTA polyester PNT enclosure | Circuit breaker | 1 feeder

This CBTA switchboard is mounted in an insulated PNT polyester enclosure with a moulded case circuit breaker.

  • Outgoing directly from the circuit breaker.
  • Suitable for power transformers from 400 kVA up to 1000 kVA.

Specifications of the CBTA PNT Premium – Circuit breaker:

Incoming Top, directly to load breaker
Rated current 630/800/1000/1250/1600 A
Installation Indoor
Enclosure Polyester PNT
Operation Moulded case circuit breaker
Outgoing types Directly from the circuit breaker
No. of outgoings 1
Options · Incoming plates for 3/4 cables per phase.
· Auxiliary circuit.
No. of incoming cables 2 x 240 mm2
3 x 240 mm2
4 x 240 mm2

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información

CBTA M | Circuit breaker | 1 Outgoing

Metallic Enclosure CBTA
Circuit breaker | 1 Outgoing

  • Suitable for power transformers from 1250 kVA hasta 2000 kVA.

Specifications:

Incoming Top
Rated current 2000 A 2500 A 3200 A
Installation Indoor
Enclosure Metallic (height 1250 mm)
Operation 3P+N moulded case circuit breaker
Outgoing types Directly from the circuit break
No. of outgoings 1
Options · Auxiliary circuits
· Locking device for switch
· Residual current protection
No. of incoming cables 8 x 240 mm2
Weight 105 kg 125 kg 135 kg

 

más información