CBTA envolvente poliéster | Load break switch | 4 feeders

CBTA using insulated PNT polyester enclosure is assembled in one cabinet with two independent doors:

  • Upper enclosure for the load break switch.
  • Lower enclosure for the feeders by means of fuse switches BTVC TRIVER+.

Suitable for power transformers up to 400 kVA.

Specifications of the CBTA PNT Premium – Load break switch:

Incoming Bottom directly to load break switch
Rated current 400/630 A
Installation Outdoor-Indoor
Enclosure Polyester PNT
Operation 3F+N load break switch
Outgoing types BTVC TRIVER+*
No. of outgoings 4
Options
  • Pole mounting frame
  • Locking device
No. of incoming cables 2 x 240 mm2
Weight 75 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTA polyester PNT enclosure | Circuit breaker | 1 feeder

This CBTA switchboard is mounted in an insulated PNT polyester enclosure with a moulded case circuit breaker.

  • Outgoing directly from the circuit breaker.
  • Suitable for power transformers from 400 kVA up to 1000 kVA.

Specifications of the CBTA PNT Premium – Circuit breaker:

Incoming Top, directly to load breaker
Rated current 630/800/1000/1250/1600 A
Installation Indoor
Enclosure Polyester PNT
Operation Moulded case circuit breaker
Outgoing types Directly from the circuit breaker
No. of outgoings 1
Options · Incoming plates for 3/4 cables per phase.
· Auxiliary circuit.
No. of incoming cables 2 x 240 mm2
3 x 240 mm2
4 x 240 mm2

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información

CBTA M | Circuit breaker | 1 Outgoing

Metallic Enclosure CBTA
Circuit breaker | 1 Outgoing

  • Suitable for power transformers from 1250 kVA hasta 2000 kVA.

Specifications:

Incoming Top
Rated current 2000 A 2500 A 3200 A
Installation Indoor
Enclosure Metallic (height 1250 mm)
Operation 3P+N moulded case circuit breaker
Outgoing types Directly from the circuit break
No. of outgoings 1
Options · Auxiliary circuits
· Locking device for switch
· Residual current protection
No. of incoming cables 8 x 240 mm2
Weight 105 kg 125 kg 135 kg

 

más información

CBTA M | Circuit breaker | 8 Outgoings

Metallic Enclosure CBTA
Circuit breaker | 8 Outgoings

  • 8 feeders by means of BTVC TRIVER+.
  • Suitable for power transformers from 1250 kVA up to 2000 kVA.
  • It can be extended with a CBTA-AM Extension module.

Specifications:

Incoming Top
Rated current 2000 A 2500 A 3200 A
Instalalation Indoor
Enclosure Metallic
Operation 3P+N moulded case circuit breaker
Outgoing types BTVC TRIVER+*
No. of outgoings 8**
Options ·Auxiliary circuits
· Locking device for switch
· Residual current protection
No. of incoming cables 4 x 240 mm2
* BTVC – Three pole vertical fuse switch TRIVER+.
No. of outgoings, changes, when combinating the range of fuse rail switches TRIVER+ NH 00/1/2/3.
** It is possible to request the extension panel to increase the No. of outgoings.
más información

CBTA M | Load break switch | 1-2 outgoings

Metallic Enclosure CBTA
Load break switch

  • Feeder by means  of  one pole fuse base NH 4. Available 1 feeder of 3150 A or 2 feeders of 1600 A
  • Suitable for power transformers from 1250 kVA  up to 2000 A.

Specifications:

Incoming Top
Rated current 2000 A 2500 A 3150 A
Installation Indoor
Enclosure Metallic
Operation 3P+N load break switch
Outgoing types One pole fuse bases NH 4
No. of outgoings 1-2
Options
·  Auxiliary circuits
·  Locking device for switch
No. of incoming cables 8 x 240 mm2

 

más información

CBTA M | Load break switch | 8 Outgoings

Metallic Enclosure CBTA
Load break switch | 8 Outgoings

  • 8 feeder by means of BTVC TRVIER+.
  • Suitable for power transformers from 1250 kVA  up to 2000 A.
  • It can be extended with a CBTA-AM module.

Specifications:

Incoming Top
Rated current 2000 A 2500 A 3150 A
Installation Indoor
Enlosure Metallic
Operation Interruptor de corte en carga 3F+N
Outgoing types BTVC TRIVER+*
No. of outgoings 8
Options
· Auxiliary circuits
. Locking device for switch
No. of incoming cables 8 x 240 mm2

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información