PRODUCTOS

Archives

CBTA-AM Metallic | Extension LV Distribution Panel

Metallic CBTA-AM Enclosure
Extension LV Distribution panel | 6 Outgoings

  • Extension module for CBTAs with 8 outgoings (see here).
  • 6 feeders by means of fuse switches BTVC TRIVER+.

Specifications:

Incoming Lateral from the switchboard by means of extension plates
Rated current 2000 A 2500 A 3200 A
Installation Indoor
Enclosure Metallic
Operation
Outgoing types BTVC TRIVER+*
No. of outgoings 6
Options
No. of incoming cables Connection with CBTA by means of extension plates

* BTVC-Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse rail switches
TRIVER+ NH 00/1/2/3.

más información

CBTA-AM UNESA | Extension LV Distribution Panel

CBTAUAM-400*400

Metallic UNESA CBTA-AM Enclosure
Extension LV Distribution panel | 4 Outgoings

  • Extension module for Direct Customers CBTA Metallic UNESA type LV Panels.
  • 4 feeders by means of fuse switches BTVC TRIVER+.

Specifications:

Incoming Lateral from the LV CBTA switchboard using extension plates
Rated current 1600 A
Installation Indoor
Enclosure Metallic UNESA type
Operation
Outgoing types BTVC TRIVER+*
No. of outgoings 4
Options
No. of incoming cables Connection to the CBTA by means of extension plates
Weight 67 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información

CBTI-00

Outdoor substation LV Switchboard (pole mounted type) according to standard NI 504404. Feeders by means of fuse switches NH 00 BTVC TRIVER+ (160 A). Maximum cross-section for the outgoing cable 95 mm2. Incoming and outgoing connections through the bottom of the enclosure.

Specifications of the CBTI-00:

Incoming Bottom
Rated current 250 A
Installation Outdoor
Enclosure PNT Polyester
Operation
Outgoing types BTVC TRIVER+ NH 00
EM 100 mm
No. of outgoings 2 3
Options Mounting frame
No. of incoming cables 1 x 240 mm2
Weight 12 kg 16 kg

 

más información

CBTI

Outdoor substation LV Switchboard (pole mounted type) according to standard NI 504404. Feeders by means of fuse switches NH 00 BTVC TRIVER+ (160 A). Maximum cross-section for the outgoing cable 95 mm2. Incoming and outgoing connections through the bottom of the enclosure.

Specifications of the CBTI:

Incoming
Through the bottom part of the
switchboard directly to the busbar
Rated current 630A
Installation Outdoor
Enclosure PNT Polyester
Operation
Outgoing types BTVC TRIVER+*
No. of outgoings 3
Options Auxiliary circuit
No. of incoming cables 2 x 240 mm2
Weight 22 kg
* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTA | PNT Premium | Circuit breaker

The CBTA PNT Premium is assembled using an insulated enclosure which contains a circuit breaker .

  • Suitable for power transformer up to 400 kVA.
  • Auxiliary circuit service as an option.

Specifications of the CBTA PNT Premium – Circuit breaker:

Incoming Top, directly to the switch
Rated current Hasta 630 A
Installation Indoor – Wall mounted
Enclosure PNT Premium
Operation 3F+N Circuit break
Outgoing types Directly from the circuit breaker
No. of outgoings 1
Options Auxiliary circuits
No. of incoming

cables

Up to 2 x 240 mm2

 

 

más información

CBTO-AS4

Specifications of the AS4:

Incoming Top
Rated current  1600 A
Installation  Indoor
Enclosure Metallic frame
Operation  3P+N Single pole disconnector
Outgoing types  BTVC TRIVER+*
No. of outgoings 4
Options  Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight  80 kg

 

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información