PNT Premium polyester

General data:

Materials Insulated, recyclable thermoplastic
and self-extinguishing
General data IP65 standard
IP43 sealing
IK10
European standard UNE-EN 20324

Properties:

  • Excellent termal and mechanical properties
  • Strong flame resistance
  • Suitable for outdoor applications, resistant to UV radiation

Features:

  • New esthetical design. Thanks to its curved door design this enclosures offers a frontal IK10 protection degree in compliance with LV regulations.
  • The L version comes with triangular double locking system. S and M sized enclosures are available with a single locking system.
  • Door includes top/bottom catchers, securing closure of door without using keylock.
  • Triple hinged doors in the small version and four hinges in sizes M and L. The multiple hinged system improves maneuverability and strength of the doors preventing displacement or difficulties in their operations.
  • Door opens to 180º. Lockable at 900 and 180º.

Range:

Available in 3 sizes: S/M/L. Different options with closed or opened bottom with removable plate (3).

Extra sealing to increased IP rating is available:

  • Standard IP rating: IP43 (1)
  • With extra sealing: IP65 (2)

Optional extra ventilation for IP43 enclosures.

Applications:

  • Electrical sector: House connections boxes, LV distribution boards for public/private indsutrial customers, photovoltaic connection panels, Metering boxes…
  • Other sectors: Telecomuninications, water applications, gas applications…

 

más información

PNT ALP 17 – 2P

Application of the PNT ALP 17 – 2P (2 front doors) in concrete enclosure is:  outdoor lightning installations, LV distribution panels or other uses like water meters, photovoltaic installations, traffic regulation, telephone, etc.

Cabinet has 2 front doors. Lock is located in the left door and right door has 2 locking latches.

No internal partition.

  • External dimensions | 1700 x 1780 x 480 mm
  • Metering frame/lighting circuits | 985 x 1100 mm
  • Discharge regulator mounting plate  | 500 x 1100 mm*
  • Visible height | 1560 mm
  • Minimum excavation dimensions | 220 x 1750 x 500 mm

* Please, consct us for other dimensions.

Cabinets material Reinforced concrete
Door material  Galvanised & painted steel sheet
Protection degree IK10, IP55
Handling system  Two eye bolts for crane handling.
Earthing Doors and frame are connected together for earthing.
Wiring  Cable access to the cabinet is made through the cabinet base, which provides earth connection
Constructive characteristics (mechanical resistance)
The PNT ALP 17 features the following mechanical characteristics:
– The vertical walls are capable of supporting their own weight, the roof, and its overload, as well as a horizontal pressure weight of 100 kg/m2.
– The roof supports loads of 250 kg/m2.
Ne weight 1015 kg

 

más información

EDP HC Energy

Range of  Pronutec’s LV Swtichboards in Polyester enclosure includes EDP HC Energy models:

  • PNT 1010 2 doors (105) | 1000 x 1000 x 300 mm
más información

CGP 250 A

Range of House connection boxes of 250 A counts with seven models of NH 1 size:

PNT designation No. of fuse bases Size Enclosure
CGP-7-250 3 1 S
CGP-8-250 3 1 L
CGP-9-250 3 1 L
CGP-10-250 3 1 D/G
CGP-11-250 3/3 1 E
CGP-11-250/250 3/3 1 E
CGP-11-250/250/400 3/3 1 F/H
CGP-12-250/250 3/3 1 F
CGP-12-250/400 3/3 1 F
CGP-14-250 3 1 L

 

más información

PNT ALP 17 – 3P F

Application of the PNT ALP 17 – 3P F (3 front doors) in concrete enclosure is: metering, lightning circuits and discharge regulator of an outdoor lightning installation. Cabinet has three front doors, one for access to metering partition and two for access to the lighting installation.

Lock is located behind the central door. Right door has two locking latches. Metering and lighting partitions are independent and each access door has its own key.

  • External dimensions | 1700 x 1780 x 480 mm
  • Metering mounting plate | 350 x 1100 mm
  • Lighting mounting plate | 590 x 1100 mm*
  • Discharge regulator mounting plate | 500 x 1100 mm*
  • Visible height  | 1560 mm
  • Minimum excavation dimensions | 220 x 1750 x 500 mm

* Please, contact us for other dimensions.

Cabinets material Reinforced concrete
Door material
Galvanised
Ptotection degree IK10, IP55
Handling system
Two eye bolts for crane handling.
Earthing Doors and frame are connected together for earthing.
Wiring Cable access to the cabinet is made through the cabinet base, which provides earth connection.
Cosntructive characteristics (mechanical resistance) The PNT ALP 17 features the following mechanical characteristics:

– The vertical walls are capable of supporting their own weight, the roof, and its overload, as well as a horizontal pressure weight of 100 kg/m2.
– The roof supports loads of 250 kg/m2.
Net weight 1035 kg

 

más información

PNT ALP 17 – 3P (2P F – 1P T)

Application of the PNT ALP 17 – 3P (2 front doors – 1 back door) in concrete enclosure is: metering, lightning circuits and discharge regulator of a outdoor lightning installation.

Cabinet has a back door for access to measuring partition and two frontal doors access to lighting installation. Lock is located in the left front door. Right front door has 2 locking latches. Back door and left frontal door have their own key.

Metering and lighting partitions are independent.

  • External dimensions | 1700 x 1780 x 480 mm
  • Metering mounting plate | 590 x 1100 mm
  • Lighting mounting plate | 420 x 1100 mm*
  • Discharge regulator mounting plate | 500 x 1100 mm*
  • Visible height | 1560 mm
  • Minimum excavation dimensions | 220 x 1750 x 500 mm

* Please, contact us for other dimensions.

 

Cabinets material Reinforced concrete
Door material Galvanised
Protection degree IK10, IP55
Handling system Two eye bolts for crane handling.
Earthing Doors and frame are connected together for earthing.
Wiring Cable access to the cabinet is made through the cabinet base, which provides earth connection.
Constructive characteristics (mechanical resistance) The PNT ALP 17 features the following mechanical characteristics:

– The vertical walls are capable of supporting their own weight, the roof, and its overload, as well as a horizontal pressure weight of 100 kg/m2.
– The roof supports loads of 250 kg/m2.
Net wight 1050 kg

 

más información