PRODUCTOS

Archives

ADU PNT Enclosure

LV Distribution board with incoming and outgoing through the bottom part. Feeders by means.

Specifications:

Incoming By means of a three pole fuse switch or directly to busbar
Rated current 630 A in standard
(Contact us for further options)
Installation Outdoor
Enclosure Polyester PNT
Type of outgoings BTVA / BTVC TRIVER+*
No. of outgoings 3/5/7**
Options Control
Mounting frame
No. of incoming cables 2 x 240 mm2

* BTVA/BTVC – Three pole vertical fuse switch TRIVER+.
No. of outgoings, changes, when combinating the range of fuse/rail switches TRIVER+ NH 00/1/2/3.
** Standard No. of outgoings. Please, contact us for other options.

más información

CGP 160 A

Range of House connection boxes of 160 A counts with four models of NH 00 sizes:

PNT designation No. of fuse bases Size Enclosure
CGP-1-160 1 00 S
CGP-7-160 3 00 M
CGP-8-100 3 00 M
CGP-9-100 3 00 M

 

más información

CGP 100 A

Range of House connection boxes of 100 A counts with four models on NH 00 sizes:

PNT designation No. of fuse bases Size Enclosure
CGP-1-100 1 00 S
CGP-7-100 3 00 M
CGP-8-100 3 00 M
CGP-9-100 3 00 M

 

más información

CGP 400 A

Range of House connection boxes of 400 A counts with seven models on NH 2 size:

PNT designation No. of fuse bases Size Enclosure
CGP-7-400 3 2 L
CGP-8-400 3 2 L
CGP-9-400 3 2 L
CGP-10-400 3 2 D
CGP-10-400/400 3 2 D
CGP-14-400 3 2 L
CGP-14-400/400 3 2 L
CS NHC-400 3 2 L

 

más información

Interconnectin cabinet

LV distribution board in PNT polyester enclosure with a coupled busbar to connect two different panels (incoming-net, outgoing-net / customers).

Specifications:

Interconnection By means of a disconnector BTVC-S (with solid link)
Incoming By means of a fuse switch BTVC TRIVER+
Rated current 630 A in standard
(Contact us for further options)
Installation Outdoor
Enclosure Polyester PNT
Outgoing types BTVA / BTVC TRIVER+*
No. of outgoings 4/6**
Options Mounting frame
No. of incoming cables 1 x 240 mm2

* BTVA/BTVC – Three pole vertical fuse switch TRIVER+.
No. of outgoings, changes, when combinating the range of fuse/rail switches TRIVER+ NH 00/1/2/3.
** Standard No. of outgoings. Please, contact us for other options.

más información

ADU PNT Enclosure

LV Distribution board with incoming and outgoing through the bottom part. Feeders by means.

Specifications:

Incoming By means of a three pole fuse switch or directly to busbar
Rated current 630 A in standard
(Contact us for further options)
Installation Outdoor
Enclosure Polyester PNT
Type of outgoings BTVA / BTVC TRIVER+*
No. of outgoings 3/5/7**
Options Control
Mounting frame
No. of incoming cables 2 x 240 mm2

* BTVA/BTVC – Three pole vertical fuse switch TRIVER+.
No. of outgoings, changes, when combinating the range of fuse/rail switches TRIVER+ NH 00/1/2/3.
** Standard No. of outgoings. Please, contact us for other options.

más información