Outdoor substation LV Switchboard (pole mounted type) according to standard NI 504404. Feeders by means of fuse switches NH 00 BTVC TRIVER+ (160 A). Maximum cross-section for the outgoing cable 95 mm2. Incoming and outgoing connections through the bottom of the enclosure.

Specifications of the CBTI:

Incoming
Through the bottom part of the
switchboard directly to the busbar
Rated current 630A
Installation Outdoor
Enclosure PNT Polyester
Operation
Outgoing types BTVC TRIVER+*
No. of outgoings 3
Options Auxiliary circuit
No. of incoming cables 2 x 240 mm2
Weight 22 kg
* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTA | PNT Premium | Circuit breaker

The CBTA PNT Premium is assembled using an insulated enclosure which contains a circuit breaker .

  • Suitable for power transformer up to 400 kVA.
  • Auxiliary circuit service as an option.

Specifications of the CBTA PNT Premium – Circuit breaker:

Incoming Top, directly to the switch
Rated current Hasta 630 A
Installation Indoor – Wall mounted
Enclosure PNT Premium
Operation 3F+N Circuit break
Outgoing types Directly from the circuit breaker
No. of outgoings 1
Options Auxiliary circuits
No. of incoming

cables

Up to 2 x 240 mm2

 

 

más información

CBTO-AS4

Specifications of the AS4:

Incoming Top
Rated current  1600 A
Installation  Indoor
Enclosure Metallic frame
Operation  3P+N Single pole disconnector
Outgoing types  BTVC TRIVER+*
No. of outgoings 4
Options  Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight  80 kg

 

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

 

más información

CBTO-AL5

Specifications of the AL5:

Incoming LateralSuperior
Rated current 1600 A
Installation Indoor
Enclosure Metallic frame
Operation 3P+N Single pole disconnector
Outgoing types BTVC TRIVER+*
No. of outgoings 8
Options  Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight 85 kg

 

* BTVC – Bases TRIVER+ tripolar vertical desconectable en carga.
El nº de salidas varía según se combine la gama del catálogo de bases
TRIVER+ NH 00/1/2/3.

 

más información

CBT-AC4

CBT-AC4 LV has low voltage switchboard with cut out plates as main operation. Suitable for transformers up to 1000 kVA. It’s possible to connect to a power generation  and it can be extended with a CBT-AM4.

The CBT-AC4 of UNESA has two different types:

  • CBT-AC4
  • CBT-AC4 SOS | It allows the connection of an auxiliary connection device (2 x 240 mm2 per phase) with an IP2X.

Specifications of the CBT-AC4:

Incoming Top
Rated current 1600 A
Installation Indoor
Enclosure Metallic
Operation Cut out plates
Types of outgoings BTVC TRIVER+*
No. of outgoings 4
Options Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight 120 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información

CBTA Premium PNT enclosure | Load break switch | 1 feeder

On this model, the CBTA PNT Premium is assembled using an insulated enclosure which contains a load break switch combined with one pole fuse bases NH type.

  • Suitable for power transformer up to 250 kVA.
  • Auxiliary circuit service is optional.

Specifications of the CBTA PNT Premium – Load break switch:

Incoming Top, directly to the switch
Rated current Up to 400 A
Installation Indoor – Wall mounted
Enclosure PNT Premium
Operation CBTA PNT Premium – Load break switch
Outgoing types One pole NH fuse bases
No. of outgoings 1
Options Auxiliary Circuits
No. of incoming cables 1 x 240 mm2

 

más información