CBTO-AS4

LV panel with 3P+N vertical disconnector with upper incoming connection, an additional power supply (for emergency purposes) and four fuse swiches size NH 1/2/3.  Specifications of the AS4:

más información

CBTO-AL5

Specifications of the low voltage panel CBTO- AL5:

 

más información

* BTVC – Bases TRIVER+ tripolar vertical desconectable en carga.
El nº de salidas varía según se combine la gama del catálogo de bases
TRIVER+ NH 00/1/2/3.

más información

CBT-AC4

CBT-AC4 LV has low voltage switchboard with cut out plates as main operation. Suitable for transformers up to 1000 kVA. It’s possible to connect to a power generation  and it can be extended with a CBT-AM4.

The CBT-AC4 of UNESA has two different types:

  • CBT-AC4
  • CBT-AC4 SOS | It allows the connection of an auxiliary connection device (2 x 240 mm2 per phase) with an IP2X.

Specifications of the CBT-AC4:

Incoming Top
Rated current 1600 A
Installation Indoor
Enclosure Metallic
Operation Cut out plates
Types of outgoings BTVC TRIVER+*
No. of outgoings 4
Options Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight 120 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información

CBTA Premium PNT enclosure | Load break switch | 1 feeder

On this model, the CBTA PNT Premium is assembled using an insulated enclosure which contains a load break switch combined with one pole fuse bases NH type.

  • Suitable for power transformer up to 250 kVA.
  • Auxiliary circuit service is optional.

Specifications of the CBTA PNT Premium – Load break switch:

Incoming Top, directly to the switch
Rated current Up to 400 A
Installation Indoor – Wall mounted
Enclosure PNT Premium
Operation CBTA PNT Premium – Load break switch
Outgoing types One pole NH fuse bases
No. of outgoings 1
Options Auxiliary Circuits
No. of incoming cables 1 x 240 mm2

 

más información

CBT-AC-I

Low voltage switchboard with 3P+N load break as incomer. Suitable for transformers up to 1000 kVA.
It can be extended with the CBT-AM4. Available in 1 or 2 modules.

Specifications of the CBT-AC-I:

1 module 2 modules
Incoming Top
Rated current 1600 A
Installation Indoor
Enclosure Metallic
Operation 3P+N load break switch
Outgoing types BTVC TRIVER+*
No. of outgoings 4 8
Options Auxiliary circuits
No. of incoming cables 4 x 240 mm2
Weight 130 kg 210 kg

* Three pole vertical fuse switch TRIVER+.
No. of outgoings changes when combinating the range of fuse switches
TRIVER+ NH-00/1/2/3.

más información