PRODUCTOS

Archives

CBTO-AS8

CBT0-AS8

The aim of the CBTO ECOLAN LV Switchboard is to spread the LV supply from the distribution transformer into several independent feeders by means of fuse switches BTVC TRIVER+.

The main parts are: 3P+N vertical disconnector with upper incoming connection, an additional power supply (for emergency purposes), an insulating panel, fuse switches (BTVC TRIVER+) and auxiliary circuits (measurement, substation services, etc.). In case of floor fixing it comprises a metallic frame. The incoming connection is designed for 4 cables of 240 mm2 per phase and 3 cables of 240 mmfor the neutral.

 

No. of outgoings changes when combinating the range of fuse switches TRIVER+ NH-00/1/2/3.

BTVC – TRIVER+ is the brand of our range of Vertical three-pole fuse switches that can be disconnected on Load.

 

más información

NH 2 | 400 A

Three pole horizontal design fuse switch disconnector NH2 size

  • NH2 size
  • Rated operational current up to 400 A.
  • Option of busbar or panel mounting depending on the model.
  • Bottoom / top connection

 

This range of horizontal fuse switches offers the option of Fuse Fuse Control System (FSC):

  • Monitoring system for detection of blown fuses (3 phases).
  • Electronic and electromechanical version included in the fuse holder.
  • Auxiliary energy not required.
  • Possibility of outgoing signal through potential-free auxiliary contacts if one or more fuses get blown.
  • Short response time.
más información

NH 3 | 630 A

Three pole horizontal design fuse switch disconnector NH3 size

  • NH3 size
  • Rated operational current up to 630A.
  • Option of busbar or panel mounting depending on the model.
  • Bottoom / top connection

 

This range of horizontal fuse switches offers the option of Fuse Fuse Control System (FSC):

  • Monitoring system for detection of blown fuses (3 phases).
  • Electronic and electromechanical version included in the fuse holder.
  • Auxiliary energy not required.
  • Possibility of outgoing signal through potential-free auxiliary contacts if one or more fuses get blown.
  • Short response time.
más información

NH 00 | 185 mm | 800 V

Vertical three pole fuse switches for NH00 size fuses. Fuse switches for photovoltaic applications.

  • Distance between busbars of 185 mm.
  • Rated operational current up to 125 A.
  • Rated operational voltage up to 800 V AC.
  • Depending on the type of model, this range of fuse switches offers the option of one pole disconnection (DU), allowing individual disconnection of each phase or the option of three pole disconnection (DT), disconnecting all three phases simultaneously.
  • Top / bottom reversible connection.
más información

NH 1/3 | 185 mm | 800 V

Vertical three pole fuse switches for NH1/3 size fuses. Fuse switches for photovoltaic applications.

  • Distance between busbars of 185 mm.
  • Rated operational current up to 500 A.
  • Rated operational voltage up to 800 V AC.
  • Depending on the type of model, this range of fuse switches offers the option of one pole disconnection (DU), allowing individual disconnection of each phase or the option of three pole disconnection (DT), disconnecting all three phases simultaneously.
  • Top / bottom reversible connection.

 

más información