ILF G2
Live Network LV phase and feeder identifier
- Three Pole Horizontal fuse bases and fuse switch disconnectors
- Switchboards for Transformer Substations
- Earth Joint Box
- Street lighting cabinets
- Three pole horizontal open/protected fuse bases
- CBTA Insulated box
- Diazed
- Concrete enclosure
- CBTA UNESA
- Isolated enclosures
- CBTA UNESA | Circuit breaker
- CBTA-M Metallic | Load break switch
- Other Smart Grids Solutions
- PV in AC | Switchgear and combiner panels
- Other Energy Monitoring Devices
- CBTO Optimized
- MV & LV cable identifier
- Outdoor photovoltaic boxes
- Smart Fuse Switch (SFS)
- One pole open/protected fuse bases
- CBTR Indoor frame mounted LV Panel
- Earth connection boxes
- Three pole horizontal design fuse switch disconnectors - BTHC
- CBTA Metallic enclosure
- Polyester enclosure
- Vertical design fuse rails and fuse switches
- Neozed
- CGP - House Connection Boxes
- Vertical design fuse rails
- Concrete cabinets
- CBTA-M Metallic
- PV in DC up to 1500 V
- LV Panels for solar plants DC
- Global Low Voltage Monitoring System
- Underground Cable and Pipe Locator
- Indoor photovoltaic boxes
- SIC - Integrated Compact Disconnector
- CBTA-M Metallic | Circuit breaker
- One pole LV fuse switches – NHC
- CBTA UNESA | Load break switch
- CUMA 21 LV Modular Insulated Panel
- Other applications
- Vertical design fuse switches for 800 V AC applications
- CBTA PNT Premium
- 1 Pole fuse bases
- CBTI Outdoor Substation’s LV Switchboard
- Live Network LV phase and feeder identifier
- 1 pole and 2 pole fuse bases for DC
- ETI | Fuse links and Fuse disconnectors
- Cabinets for Telemanagement and Telecommunication
- ADU- Outdoor LV Distribution Boards
- Fuse bases and fuse switches for photovoltaic DC
- Enclosures
- Vertical design fuse switches and disconnectors TRIVER+
- CBTA PNT Polyester
- Distribution Transformer monitoring systems
- Genset Power Connector - GPC
- Accessories for fuse switches
- CMAT - Metering panels
- Other equipments
- IP20 protected busbar system
- Energy Monitoring Devices
- CBT UNESA
- NH 00 | 160 A | 185 mm
- CBTI-T-Telemanagement Outdoor Substation’s LV Switchboard
- Other panels for Utility
- Range
- NH 1/2/3 | 250/400/630 A | 185 mm
- Smart grids
- Photovoltaic AC / DC
- LV distribution panels
- Distribution panels for Utility
- Other products
- ETI Fue links and modular switchgear
- Merytronic | Portable devices
- NH Fuse switches
- Distribution network
DESCRIPTION
Phase and feeder identifier
The ILF G2 device, phase and feeder identifier, makes it possible to identify in a few seconds and with total reliability, to which Secondary Substation, Low Voltage panel, feeder output and phase each of the meters/subscribers of the Low Voltage electric grid are connected.
This information package is known as meter topology. The electric utilities knowledge of the topology of its subscribers is crucial for the correct management of its distribution networks.
In addition to determining the topology of the meters, intermediate elements of the network can also be identified.
The identification is carried out with the network in service, for any type of network: ringed, star, with/without neutral, triangle, etc.
The device consists of a CD – central unit that is installed in the Secondary Substation and a UL – line device that will be carried by the operator where the topology package is displayed. It is possible for several operators to work at the same time under the same CD, each with their own UL.
There is an advanced version of the device, the ILF G2 Pro. It is specially designed for large network mapping campaigns.
This new generation of identifiers allows to digitise the results obtained directly from the field. Thanks to the app GridGIS D-twin (developed by Ariadna Grid), which is sold as an option, the location and connection of all the identified points of the Low Voltage distribution network can be added, edited and stored on the same map.
Main Features
- Operation with the network in service, without de-energised.
- Identification of the 3 phases and up to 12 feeders of a LV panel.
- Identification in a few seconds, 100% reliability.
- Proven efficiency over distances > 1 km
- Suitable for any Low Voltage network configuration, up to 480 Vac between phases (50-60 Hz): Delta, Star (without neutral), coupled or ringed networks…
- Designed to work in several Secondary Substations simultaneously.
- GridGIS D-twin digitising App (optional)
- Integrated Bluetooth for data transfer
- Easy to use and configure
Others functionalities
-
Identifying the neutral
In maintenance tasks that involve disconnecting the neutral, such as, replacement Low Voltage panels, unfold feeders… A wrong identification of the neutral can have serious consequences like: imbalances between phases, overvoltage, errors when quantifying technical-losses, dangeous for people and devices (electrical safety), economic sanctions…
The ILF G2 device allows to identify the correct Neutral, in a quick and reliable way, avoiding connection/disconnection errors and improving safety. ILF G2 Pro is suitable for more than 6 lines. See document in download section.
-
Cable identification
A solution that improves electrical safety in LV energised cable handling procedures. Adding the IC2G Rx device to the ILF G2 – UL provides a Cable Identifier. A quick and easy way to have two devices in one. See document in download section.