PNT ALP 17 – 3P (2P F – 1P L)

Concrete enclosure

Description

Application of the PNT ALP 17 – 3P (2 front doors – 1 lateral door) in concrete enclosure is: metering, lightning circuits and discharge regulator of a outdoor lightning installation.

Cabinet has a side door for access to measuring partition and two front doors for access to the lighting installation. Lock is located In the left front door. Right front door has 2 locking latches. Lateral door and left frontal door has each own key.

Metering and lighting partitions are independent.

  • External dimensions | 1700 x 1780 x 480 mm
  • Metering mounting plate | 300 x 1100 mm
  • Lighting mounting plate | 762 x 1100 mm*
  • Discharge regulator mounting plate | 500 x 1100 mm*
  • Visible height | 1560 mm
  • Minimum excavation dimensions | 220 x 1750 x 500 mm

* Please, contact us for other dimensions.

Cabinet material Reinforced concrete
Door material Galvanised
Protection degree IK10, IP55
Handling ystem Two eye bolts for crane handling.
Earthing Doors and frame are connected together for earthing.
Wiring Cable access to the cabinet is made through the cabinet base, which provides earth connection.
Constructive characteristics (mechanical resistance)
The PNT ALP 17 features the following mechanical characteristics:
– The vertical walls are capable of supporting their own weight, the roof, and its overload, as well as a horizontal pressure weight of 100 kg/m2.
– The roof supports loads of 250 kg/m2.
Net weight 977 kg

 

Contact with us